From 78d13552346289bad4a9bf8eabb5eec5e5a321a5 Mon Sep 17 00:00:00 2001 From: Riwen Lu Date: Fri, 4 Jun 2021 11:09:59 +0800 Subject: hwmon: (scpi-hwmon) shows the negative temperature properly The scpi hwmon shows the sub-zero temperature in an unsigned integer, which would confuse the users when the machine works in low temperature environment. This shows the sub-zero temperature in an signed value and users can get it properly from sensors. Signed-off-by: Riwen Lu Tested-by: Xin Chen Link: https://lore.kernel.org/r/20210604030959.736379-1-luriwen@kylinos.cn Signed-off-by: Guenter Roeck --- drivers/hwmon/scpi-hwmon.c | 9 +++++++++ 1 file changed, 9 insertions(+) (limited to 'drivers/hwmon') diff --git a/drivers/hwmon/scpi-hwmon.c b/drivers/hwmon/scpi-hwmon.c index 25aac40f2764..919877970ae3 100644 --- a/drivers/hwmon/scpi-hwmon.c +++ b/drivers/hwmon/scpi-hwmon.c @@ -99,6 +99,15 @@ scpi_show_sensor(struct device *dev, struct device_attribute *attr, char *buf) scpi_scale_reading(&value, sensor); + /* + * Temperature sensor values are treated as signed values based on + * observation even though that is not explicitly specified, and + * because an unsigned u64 temperature does not really make practical + * sense especially when the temperature is below zero degrees Celsius. + */ + if (sensor->info.class == TEMPERATURE) + return sprintf(buf, "%lld\n", (s64)value); + return sprintf(buf, "%llu\n", value); } -- cgit v1.2.3